Model GA-60: Analizor portabil gaze de ardere cu 10 senzori interschimbabili

 

Solicit oferta personalizata »

⧉ Produsul poate fi achizitionat si prin SEAP

detector_scurgeri_gaze_metan
 

Analizor profesional pentru gaze de ardere cu 10 senzori pentru gaze arse si aplicatii multiple

Analizor de gaze mobil cu 10 senzori de gaze arse pentru aplicatii multiple, dispune de cele mai avansate solutii, indeosebi pentru analiza gazelor arse cu tehnologie si design de ultima ora, dotat cu noua generatie de senzori si de celulelor electrochimice cu o durata de viata mai lunga, dotat cu racitor Peltier, dispozitiv de prelevare si pregatire a gazelor si imprimanta incorporata, extrem de robust, rezistent la socuri mecanice si electromecanice, cu inchidere complet ermetica.
Se utilizeaza pentru reglajul si verificarea arderii, determinarea componentei gazelor arse la cuptoare si cazane de puteri medii si mari, conventionale sau in condensatie. Se recomanda in mod deosebit pentru arderea combustibililor solizi, monitorizari arderi de lunga durata.
Analizor de gaze GA60 poate fi achizitionat la preturi diferite in functie de nr. de senzori.
Construit conform norme europene in domeniu EN50379

Caracteristici principale

Echipat cu până la 7 celule electrochimice
Echipat cu până la 3 senzori NDIR
Panglică încorporată de 58 mm, imprimantă grafică
Măsurători ale gazului și temperaturii ambiante, opțional 8 intrări suplimentare pentru senzori de temperatură
Baterie reîncărcabilă încorporată pentru până la 8 ore de funcționare (pentru configurație de bază cu suport pentru sondă + conductă pentru sondă)
Filtru de gaz suplimentar cu sifon de condens (instalat în capac)
Senzor de presiune diferențială - pentru măsurarea tirajului coșului de fum și a vitezei de curgere (cu ajutorul tubului Pitot)
Program de măsurare funingine
Ieșiri analogice (4-20mA / 0-10V) - opțional
Data-logger card SD pentru salvarea rezultatelor
Calcule ale multor parametri suplimentari
Indicator pentru calibrarea gazelor

Analizor în versiunea A Funcționează cu suportul sondei standard Madur și țeava sondei
Posibilitatea de a lucra cu uscătoare de gaz (cum ar fi PGD-100)

Analizor în versiunea B: Uscător NAFION încorporat cu pompă peristaltică pentru îndepărtarea condensului
driver pentru furtun încălzit
Funcționează cu furtun încălzit, cu filtru de gaz încălzit încorporat și cu accesoriu standard M30x1, care se potrivește tuturor sondelor de gaz madur cu termocupluri de tip K

Portable Combustion Gas Analyzers

The largest of madur’s analysers equipped with electrochemical cells.
It can fit even up to 7 EC cells and up to 3 NDIR sensors.
GA-60 has a large (320x240), graphical LCD with backlighting.
Datalogger with SD card for storing results and built-in ribbon printer for standard (non-thermal) paper.

Analyser is offered in two versions

In basic configuration analyser is not equipped with the gas dryer and works with the probe holder + gas probe pipe. It can be paired with PGD-100 gas dryer with heated hose.
Analyser equipped with a built-in NAFION type gas dryer and heated hose - configuration especially recommended for measurement of gases highly reactive with water or disturbed by its presence (SO2, HCl, NO2, Cl2).

Main features

Equipped with up to 7 electrochemical cells
Equipped with up to 3 NDIR sensors
Built-in 58mm ribbon, graphic printer
Measurements of gas and ambient temperatures, optionally 8 additional inputs for temperature sensors
Built-in rechargeable battery for up to 8 hours of operating (for basic configuration with probe holder + probe pipe)
Additional gas filter with condensate trap (installed in the lid)
Differential pressure sensor - for measurements of chimney draft and flow velocity (with help of Pitot tube)
Soot measurement program
Analogue outputs (4-20mA / 0-10V) - optional
SD card data-logger for saving results
Calculations of many additional parameters
Aplication for gas calibration

For analyser in A version

Works with madur standard probe holder and probe pipe
Possibility to work with full-size gas dryers (like PGD-100)
For analyser in B version:
Built-in NAFION dryer with peristaltic pump for condensation removal
Driver for heated hose
Works with heated hose with built-in heated gas filter and with standard M30x1 fitting, that fits all madur gas probes with K-type thermocouples

General parameters

Versiune A (fara uscator integrat)

Dimensions (W x H x D) 500 x 395 x 173mm
Weight (without accessories) 12.2 ÷ 13.2 kg
Casing's material Plywood covered with aluminium
Protection grade IP20
Operating conditions T: 10°C ÷ 50°C, RH: 5% ÷ 90% (non-condensing)
Storing temperature -20°C ÷ +55°C
Power supply: Input | maximal power consumption 115VAC or 230VAC | 90W (without heated hose)
Battery: type | work time | charging time Lead-acid, rechargeable 3x6V / 4.5Ah | 16h | 12h
Data memory: type | size | number of results SD flash card | max 4GB | practically unlimited
Display Graphical LCD 320 x 240, with variable contrast and back-light
Printer High-speed dot matrix, graphic printer for 2.25” (57.5 ± 0.5mm) normal paper
Gas pump | gas flow Diaphragm, max 2l/min (with automatic flow control) | 90l/h (1.5l/min)
Purging pump for CO sensor Diaphragm, max 1.5l/min
Communication interface with PC computer RS-232C
Gas filtering Built-in final filter with replaceable insert

Version B (cu uscator integrat Nafion®)

Weight (without accessories) 13.7 ÷ 14.7 kg
Gas filtering 1. Heated filter included in the heated hose
2. Built-in final filter (behind the gas dryer) with replaceable insert

2. Uscator de gaze integrat; driver si incalzitor de furtun

Concerns only the B version (with built-in Nafion® dryer)

Dryer type Based on Nafion® exchanger
Drying method Water transfer through Nafion® membrane driven by partial vapour pressure differential – first order kinetic reaction
Maximum gas flow for efficient drying 100 l/h
Heated hose temperature +120°C electronically stabilised
Heated hose temperature hysteresis ~ 5°C
Heated hose length 3m (optionally 5m or 10m)
Heated hose power consumption 360W (max)
Heated hose thermocouple wires K-type (S-type optionally)

3. Masurarea componentele de gaze

Table below shows the combination of all sensors/ranges.

Please mind that the maximum possible gas sensors number in a device is 7 EC and 3 NDIR

Component Method Range | Resolution Accuracy Time(T90) Conformity
O2 – Oxygen Electrochemical sensor 20.95% | 0.01% ±0.1% abs. or 5% rel. 45 sec ISO 12039, CTM-030
O2 – Oxygen Electrochemical, partial pressure 20.95% | 0.01% ±0.1% abs. or 5% rel. 45 sec ISO 12039, CTM-030
O2 – Oxygen Electrochemical, partial pressure 25.00% | 0.01% ±0.1% abs. or 5% rel. 45 sec ISO 12039, CTM-030
O2 – Oxygen Electrochemical, partial pressure 100.00% | 0.1% ±0.1% abs. or 5% rel. 45 sec ISO 12039, CTM-030
CO – Carbon monoxide Electrochemical sensor 4 000ppm | 1ppm ±5ppm abs. or 5% rel. 45 sec ISO 12039, CTM-030
CO – Carbon monoxide Electrochemical sensor 20 000ppm | 1ppm ±5ppm abs. or 5% rel. 45 sec ISO 12039, CTM-030
CO – Carbon monoxide Electrochemical sensor 10% | 0.001% ±50ppm abs. or 5% rel. 45 sec ISO 12039, CTM-030
CO – Carbon monoxide Electrochemical,
with H2 compensation
4 000ppm | 1ppm ±5ppm abs. or 5% rel. 45 sec ISO 12039, CTM-030
CO – Carbon monoxide NDIR 10% | 0.01% ±0.05% abs. or 5% rel. 45 sec ISO 12039, Method 10
CO – Carbon monoxide NDIR 100% | 0.1% ±0.5% abs. or 5% rel. 45 sec ISO 12039, Method 10
CO2 – Carbon dioxide NDIR 5% | 0.01% ±0.05% abs. or 5% rel. 45 sec ISO 12039
CO2 – Carbon dioxide NDIR 25% | 0.01% ±0.05% abs. or 5% rel. 45 sec ISO 12039
CO2 – Carbon dioxide NDIR 100% | 0.1% ±0.5% abs. or 5% rel. 45 sec ISO 12039
CH4 – Methane NDIR 5% | 0.01% ± 0.3% abs. or 3% rel. 45 sec x
CH4 – Methane NDIR 25% | 0.01% ± 0.3% abs. or 3% rel. 45 sec x
CH4 – Methane NDIR 100% | 0.1% ± 0.3% abs. or 3% rel. 45 sec x
NO – Nitric oxide Electrochemical sensor 1 000ppm | 1ppm ±5ppm abs. or 5% rel. 45 sec EN 50379, CTM-022
NO – Nitric oxide Electrochemical sensor 5 000ppm | 1ppm ±5ppm abs. or 5% rel. 45 sec EN 50379, CTM-022
NO2 – Nitrogen dioxide Electrochemical sensor 1 000ppm | 1ppm ±5ppm abs. or 5% rel. 60 sec EN 50379, CTM-022
SO2 – Sulphur dioxide Electrochemical sensor 2 000ppm | 1ppm ±5ppm abs. or 5% rel. 45 sec EN 50379, CTM-022
SO2 – Sulphur dioxide Electrochemical sensor 5 000ppm | 1ppm ±5ppm abs. or 5% rel. 45 sec EN 50379, CTM-022
H2S – Hydrogen sulphide Electrochemical sensor 1000ppm | 1ppm ±5ppm abs. or 5% rel. 70 sec x
H2 – Hydrogen Electrochemical sensor 2 000ppm | 1ppm ±10ppm abs. or 5% rel. 50 sec x
H2 – Hydrogen Electrochemical sensor 20 000ppm | 1ppm ±10ppm abs. or 5% rel. 70 sec x
H2 – Hydrogen Thermal Conductivity Detector 10% | 0,1% ±0,5% abs. or 5% rel. 45 sec x
H2 – Hydrogen Thermal Conductivity Detector 25% | 0,1% ±0,5% abs. or 5% rel. 45 sec x
H2 – Hydrogen Thermal Conductivity Detector 50% | 0,1% ±0,5% abs. or 5% rel. 45 sec x
H2 – Hydrogen Thermal Conductivity Detector 100% | 0,1% ±0,5% abs. or 5% rel. 45 sec x
CL2 - Chlorine Electrochemical sensor 250ppm | 1ppm ±5ppm abs. or 5% rel. 60 sec x
HCl - Hydrogen chloride Electrochemical sensor 100ppm | 1ppm ±5ppm abs. or 5% rel. 70 sec x
N2O - Nitrous oxide NDIR 2 000ppm | 1ppm ±10ppm abs. or 5% rel. 45 sec ISO 21258
CHF3 – Fluoroform (Refrigerant R23) NDIR 2.5% | 0.01% ± 0.05% abs. or 5% rel. 45 s x
SO2 – Sulphur dioxide NDIR 1% | 0.01% ±5ppm abs. or 5% rel. 45 sec x
NO2 – Nitrogen dioxide NDIR 1 % | 0.01% ± 0.05% abs. or 5% rel. 45 sec x
VOC – Volatile Organic compounds PID Photo Ionization Detector 100ppm | 1ppm ±5ppm abs. or 5% rel. 120 sec Method 21
VOC – Volatile Organic compounds PID Photo Ionization Detector 1000ppm | 1ppm ±5ppm abs. or 5% rel. 120 sec Method 21

4. Determinarii diverse / Rezultate calculate

Variable Method Range | resolution Accuracy Time (T90)
Tgas – gas temperature K-type thermocouple -10 ÷ 1000°C | 0.1°C ± 2°C 10 sec
Tgas – gas temperature S-type thermocouple -10 ÷ 1500°C | 0.1°C ± 2°C 10 sec
Tamb – boiler intake air temperature PT500 resistive sensor -10 ÷ 100°C | 0.1°C ± 2°C 10 sec
Differential pressure Silicon piezoresistive pressure sensor -25hPa ÷ +25hPa | 1Pa (0.01hPa) ± 2Pa abs. or 5% rel. 10 sec
Gas flow velocity Indirect, with Pitot tube & pressure sensor 1 ÷ 50m/s | 0.1m/s 0.3m/s abs. or 5% rel. 10 sec
Lambda λ – excess air number Calculated 1 ÷ 10 | 0.01 ± 5% rel. 10 sec
qA – stack loss Calculated 0 ÷ 100% | 0.1% ± 5% rel. 10 sec
Eta η – combustion efficiency Calculated 0 ÷ 120% | 0.1% ± 5% rel. 10 sec
 